Replacing the DC fuse plug
The fuse in the DC plug (10) protects the charging circuit of the
DC Recharge Adapter. If the AC recharger operates but the DC
charging adapter does not, then the fuse may be opened. To
replace the fuse:
1. Unscrew the end cap of the
DC Plug.
2. Remove spring center contact
and fuse.
3. Check fuse with a continuity
checker.
4. If blown, locate replacement
fuse with same type and rating
(0.5A)
5. Replace the fuse, spring,
contact and end cap.
6. Screw end cap clockwise
until it is finger tight.
DO NOT OVER-TIGHTEN
7. Check for proper operation of
DC Charger Adapter.
Maintenance
Store the spotlight, instruction manual and where necessary the
accessories in the original packaging.
In this way you will always have all the information and parts
ready to hand.
Do not throw used batteries into fire or water. There is a danger
of explosion! Please hand in non-working or used batteries, or
tools with built-in batteries, to the environmentally-safe disposal
unit at a municipal waste-disposal centre, or to your dealer.
Important. All batteries lose charge over time, especially when
they are warm. AC recharge is recommended every two months,
when not in frequent use. Use the AC recharger and charge for
the recommended time.
If the unit has dirt on it, gently clean the outer surfaces of the
spotlight unit with a soft cloth moistened with a mild solution
of water and detergent. Periodically inspect the condition
of recharge adapters, connectors, and wires. Replace any
components that may have become worn or broken.